Thru-Paint Ultrasonic Wall Thickness Gauge
Total Measuring Range
Pulse-Echo Mode (Pit & Flaw Detection) - PE Mode
0.025 to 36.000 inches
0.63 to 914.4 mm
Echo-Echo Mode (Through Paint & Coatings) - EE Mode
0.100 to 1.000 inch
2.54 to 25.40 mm
(Acutal range depends upon probe selected) - five probes to choose from
Measuring Range on Steel (with standard T-102-2700 probe)
Pulse-Echo Mode (Pit & Flaw Detection) - PE Mode
0.040 to 8.00 inches
1.00 to 199.9mm
Echo-Echo Mode (Through Paint & Coatings) - EE Mode
0.100 to 1.000 inch
2.54 to 25.40 mm
The new Dakota ZX-6 Wall Thickness Gauge accurately measures wall thickness and the extent of corrosion of all metals, ceramics, glass and most rigid plastics - from only one side!When operated in E-E Mode (Thru-Paint Mode), the coating is eliminated from the reading and the gauge will display only the thickness of the metal wall.
ZX-6 Features include Automatic or Manual Probe Zero maximizing accuracy, 5-position Gain Adjustment to help located the correct backwall echo and to penetrate the walls on sound-attenuating materials such as cast metals and thick materials. It also features Differential mode, Hi-Low Alarms with audible and visual indicators and Scan mode that captures the minimum thickness at 100 measurements per second (100 Hz). It also includes a special Velocity Mode to measure in terms of velocity for nodularity testing.
The ZX-6 can be used in a Single Thickness Reading mode or in a Scan mode , where the probe is dragged over a large measuring area. The minimum thickness reading recorded during the "scan" will be displayed.
The gauge and probe have a protection rating of IP67, is impact-resistant and environmentally sealed to provide trouble-free operation under the toughest field conditions. The ZX-6 is covered by a 5-Year Limited Warranty, CE-certified and is proudly Made in the USA.
The ZX-6 can be used with any of the following hi-damped dual-element transducers specifically designed for use when employing the E-E Thru-Paint Mode. Probes possibilities include:
T-101-2700, 3/16" Diameter, 5.0 MHz Hi-damped transducer for thru paint measurement
T-101-3700, 3/16" Diameter, 7.5 MHz Hi-damped transducer for thru paint measurement
T-102-2700, 1/4" Diameter, 5.0 MHz Hi-Damped transducer for thru paint measurement - Standard Probe
T-102-3700, 1/4" Diameter, 7.5 MHz Hi-Damped Transducer for thru paint measurement
T-104-2700, 1/2" Diameter, 5.0 MHz Hi-Damped Transducer for thru paint measurement
T-104-9700, 1/2" diameter, 3.5 MHz Hi-Damped transducer for thru paint measurement

Features
- Includes both Pulse-Echo Mode (Pit & Flaw Detection) and Echo-Echo Mode (Through Paint & Coatings Mode)
- Using the standard probe T-102-2700, the gauge will read thru 0.040" coating thickness (1 mm)
- Using one of the optional probes T-104-2700, the gauge will read thru 0.075" coating thickness (1.9 mm)
- Calibrate to a sample of known thickness which automatically calculates the optimal acoustic velocity
- 2-Point Calibration to optimize linearity over a wide measurement range, automatically calculates the optimal acoustic velocity
- Scan mode, 100 readings/sec. Probe is slid over a large measuring area, the minimum thickness during the "scan" will be displayed
- Adjustable GAIN in 5 steps to fine tune the gauge for use on challenging materials or applications
- Differential mode, Hi-Low Alarms with audible and visual indicators
- User-selected Manual or Auto Zero of Transducer
- The extruded aluminum housing is impact-resistant and environmentally sealed (IP 65)
- to provide trouble-free operation under the toughest field conditions
- High visibility LCD Display is readable in all lighting conditions and temps as low as 22 °F (-30 °C)
- LCD shows Thickness Value, Velocity Setting, Gain Setting, Stability & Battery Indicators, Scan Mode, Zero, units and stored data
- Special-purpose probes are offered for a variety of applications (1 to 10 MHz)
- Single value data output via USB port
- Selectable Backlight ON/OFF/AUTO
- Resolution of 0.001 inch (0.01 mm)
- 5 Year Warranty, CE-Certified and Made in USA
- Includes NIST Traceable Calibration Certificate
Complete Kit
The ZX-6 is supplied as a complete kit with the gauge, probe, 4 oz. bottle of coupling fluid, 2 AA batteries, NIST-Traceable Calibration Certificate, and Operating Instruction Manual - all in a foam-fitted carrying case.

Specifications
Range in Steel |
Pulse-Echo Mode (Pit & Flaw Detection) measures from 0.025 to 19.999 inches
(0.63 to 500 millimeters)
Echo-Echo Mode (Through Paint & Coatings) measures from 0.100 to 1.000 inch
(2.54 to 25.40 millimeters)
(range depends upon probe selected) - five probes to choose from |
Resolution |
0.001 inch (0.01 mm) |
Velocity Range |
0.0120 to .7300 in/μs. 305 to 18,542 meters/sec |
Probe (Standard) |
1/4", 5 MHz Hi-Damp Dual Element Transducer, actual wearface is 5/8" (17mm), p/n T-102-2700 |
Probes (optional) |
1 to 10 MHz, 3/16" up to 1 inch (custom probes available) |
Probe Wearface |
PEEK (Polyethylethylkytone) |
Cable |
1.2m (4ft.) waterproof cable with non-polarized, quick-disconnect connectors |
LCD Display |
Multi-function 7 segment 4.5 digit liquid crystal display with 0.500" digit height. Two 0.125 in14 segment fields for labels and values, and one 7 segment field for labels and values. Additional icons to indicate features and modes |
Display Backlight |
Backlight is selectable on/off/auto, and selectable brightness (Lo, Med, Hi) options |
Display Update Rate |
10 Hz (10 updates/sec) |
Temp. Limits |
Ambient: -30 to 75° C (-22 to 167° F)
Material: -20 to 100° C (0 to 200° F)
High temperature probes available |
Battery Type |
2x AA batteries (rechargeable batteries can be used) |
Battery Life |
45 hours continuous use |
Weight |
308 grams (11 ounces) |
Dimensions |
63.5 x 131.3 x 31.5 mm (2.5" x 5.17" x 1.25") |
Accessories |
Probe/cable assembly, 4 oz. bottle of coupling fluid, NIST Calibration Certificate, 2 AA batteries, operating instructions, hard-plastic carrying case. |
Housing |
Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed) |
Housing Rating |
IP65 |
Certifications |
NIST Traceable and MIL-STD-45662A |
Keypad |
Sealed membrane that is resistant to both water and petroleum products
Seven or eight tactile-feedback keys |
Pulse Repetition Frequency (PRF) |
200 Hz (200 pulses/sec) |
To Lock Settings |
With gauge powered off, press and hold the "+" key while powering on the gauge
The LOCK icon will be illuminated on the Display |
To unLock Settings |
With gauge powered off, press and hold the "-" key while powering on the gauge
The LOCK icon will turn off |
GAIN Adjustment |
Adjustable GAIN 5-position (VLOW, LOW, MED, HIGH, VHI), in 3dB steps, 40-52dB |
Measuring Mode |
Pulse-Echo (P-E), Echo-Echo (E-E, Thru-Paint Mode), Scan, Differential, Alarm and VX-velocity |
Time Dependent Gain (TDG) |
Used in both pulse-echo (P-E) and Echo-Echo (E-E) modes depending on transducer and frequency selected |
Pulser |
150 volt square wave pulser |